AUTO LIGHT SENSOR INSPECTION
id091800807600
1. Measure the voltage at auto light sensor terminal A and verify that the voltage is 5 V.
2. Shine a fluorescent light or expose the auto light sensor to natural sunlight.
3. Connect the positive (+) lead to terminal B and the negative (−) lead to terminal C of the auto light sensor, and verify that the voltages are as shown in the table.
acxuuw00002401
|
acxaaw00000534
|