AUTO LIGHT SENSOR INSPECTION


id091800807600

Note
•  Inspect the auto light sensor from the back side of the connector with the connector still connected.

1.  Measure the voltage at auto light sensor terminal A and verify that the voltage is 5 V.

2.  Shine a fluorescent light or expose the auto light sensor to natural sunlight.

3.  Connect the positive (+) lead to terminal B and the negative (−) lead to terminal C of the auto light sensor, and verify that the voltages are as shown in the table.

acxuuw00002401

•  If the voltage is not as specified, replace the auto light sensor.
acxaaw00000534