SWITCH/DIAL OPERATION DOES NOT RESPOND (FRONT CLIMATE CONTROL UNIT) [FULL-AUTO AIR CONDITIONER]
id0703c1006500
DESCRIPTION
|
• Specific switch/dial operation of front climate control unit does not respond
|
POSSIBLE CAUSE
|
• Front climate control unit malfunction
• Rear window defogger switch
• Airflow volume control switch malfunction
• A/C switch system malfunction
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
VERIFY MALFUNCTION DURING EACH SWITCH/DIAL OPERATION
• Do the related parts operate according to the switch/dial operation of the front climate control unit?
|
Yes
|
Go to Step 10.
|
No
|
If specific switch/dial operation does not respond
• Go to the next step.
If all switch/dial operations do not respond
• Go to the following malfunction symptom item.
|
||
2
|
PERFORM CLIMATE CONTROL UNIT DTC INSPECTION
• Perform the climate control unit DTC inspection using the M-MDS.
• Are any DTCs displayed?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
Go to the next step.
|
||
3
|
VERIFY MALFUNCTIONING SWITCH/DIAL
• Is the switch which does not respond to being operated the rear window defogger switch?
|
Yes
|
Verify the front body control module (FBCM) DTCs.
If DTC is displayed:
• Repair the malfunctioning location according to the applicable DTC troubleshooting.
If DTC is not displayed:
• Replace the front climate control unit, then go to Step 10.
|
No
|
Go to the next step.
|
||
4
|
VERIFY MALFUNCTIONING SWITCH/DIAL
• Is any one of the following front climate control unit switch/dials the one which does not respond to being operated?
|
Yes
|
Replace the front climate control unit, then go to Step 10.
|
No
|
Go to the next step.
|
||
5
|
VERIFY MALFUNCTION DURING AIRFLOW VOLUME CONTROL SWITCH OPERATION
• Is the switch which does not respond to being operated the front climate control unit airflow volume control switch?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 7.
|
||
6
|
DETERMINE IF MALFUNCTION IS CAUSED BY FRONT BLOWER MOTOR CIRCUIT MALFUNCTION OR FRONT CLIMATE CONTROL UNIT MALFUNCTION
• Is the airflow volume setting displayed normally in the display panel after operating the front climate control unit airflow volume control switch?
|
Yes
|
Go to the following malfunction symptom item.
|
No
|
Replace the front climate control unit, then go to Step 10.
|
||
7
|
VERIFY MALFUNCTION DURING A/C SWITCH OPERATION
• Is the switch which does not respond to being operated the front climate control unit A/C switch?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 10.
|
||
8
|
DETERMINE IF MALFUNCTION IS CAUSED BY A/C OPERATION CIRCUIT MALFUNCTION OR FRONT CLIMATE CONTROL UNIT MALFUNCTION
• Is [A/C] displayed in the display panel after operating the front climate control unit A/C switch?
|
Yes
|
Go to the following malfunction symptom item.
|
No
|
Go to the next step.
|
||
9
|
VERIFY AMBIENT TEMPERATURE
• Is the ambient temperature -5 degrees C or less?
|
Yes
|
Normal (A/C does not turn on when ambient temperature is -5 degrees C or less to protect A/C compressor)
|
No
|
Replace the front climate control unit, then go to the next step.
|
||
10
|
VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR
• Do the related parts operate according to the switch/dial operation of the front climate control unit?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs.
|