PID/DATA MONITOR TABLE [SAS CONTROL MODULE (ACTIVE BONNET)]
id0802h4081000
PID |
Unit/Condition |
Data contents |
SAS control module terminal |
|
---|---|---|---|---|
PCD_A
(Poorly connected detector bar terminal voltage nominal (SAS control module connector A))
|
V
|
• Normal connected: 0.27 V or less
• Poor connected: 3.17 V or more
|
1a, 1b
|
|
PCD_B
(Poorly connected detector bar terminal voltage nominal (SAS control module connector B))
|
V
|
• Normal connected: 0.27 V or less
• Poor connected: 3.17 V or more
|
2a, 2b
|
|
PCD_C
(Poorly connected detector bar terminal voltage nominal (SAS control module connector C))
|
V
|
• Normal connected: 0.27 V or less
• Poor connected: 3.17 V or more
|
3a, 3b
|
|
VPWR_IGA
(SAS control module power voltage)
|
V
|
Ignition is switched ON: IG1 voltage
|
2AD
|
|
WLAMP_ST
(Active bonnet warning light status)
|
Lamp_Off/Lamp_On/Plant_Mode/Unknown
|
• Active bonnet warning light off: Lamp_Off
• Active bonnet warning light on : Lamp_On
• Active bonnet warning light flashing: Plant_Mode
• Active bonnet warning light unrecognized: Unknown
|
3Q, 3S
|