DTC U0001:88/U0155:00 [SAS CONTROL MODULE (ACTIVE BONNET)]


id0802h4824100

System malfunction location

•  U0001:88: Unit communication error (HS-CAN)
•  U0155:00: Communication error with instrument cluster
Detection condition
U0001:88
•  The SAS control module detects a CAN communication line (HS-CAN) error.
U0155:00
•  The SAS control module could not receive CAN signal from the instrument cluster for 5 s or more.
Fail-safe function
Not applicable
Possible cause
•  Malfunction in CAN bus communication line
•  Malfunction in CAN line between the SAS control module and instrument cluster
•  Instrument cluster malfunction
•  SAS control module malfunction
System wiring diagram
Not applicable


Diagnostic Procedure

•  Perform the malfunction diagnosis according to the troubleshooting procedure for the multiplex communication system. (See FOREWORD [L.H.D.].)(See FOREWORD [R.H.D.].)(See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [L.H.D.])(See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [R.H.D.].)