D-PILLAR REINFORCEMENT (LOWER) INSTALLATION [PANEL REPLACEMENT]


id098008829400


Symbol Mark

ac8wzb00000214

Installation Procedure

1.  Before installing the new part, drill holes for plug welding in 5 locations in area A.

2.  When installing the new part, measure the dimensions of each part following the body dimensions and align with the basic dimension.

3.  After temporarily installing the new parts, make sure the related parts fit properly.

4.  Plug welds in the 5 locations in area A shown in the figure.

5.  Spot welds in the 34 locations in area B shown in the figure and install the D pillar reinforcement (lower).