NON-RETURN VALVE INSPECTION [MZI-3.7]
id0114d2815300
1. Complete the “BEFORE SERVICE PRECAUTION”. (See BEFORE SERVICE PRECAUTION [MZI-3.7].)
2. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [MZI-3.7].)
3. Remove the fuel pump unit. (See FUEL PUMP UNIT REMOVAL/INSTALLATION [MZI-3.7].)
4. Siphon the fuel from the fuel tank.
5. Verify that the non-return valve is closed.
ac9wzw00001667
|
6. Verify that the non-return valve is not stuck open and does not open even when pulled up by a finger.