REFRIGERANT PRESSURE SWITCH REMOVAL/INSTALLATION
id074000802600
1. Disconnect the negative battery cable.
2. Discharge the refrigerant from the system. (See REFRIGERANT RECOVERY.) (See REFRIGERANT CHARGING.)
3. Grasp the piping block using pliers and remove the pressure switch using a spanner.
4. Disconnect the refrigerant pressure switch connector.
5. Remove in the order indicated in the table.
ac9wzw00001704
|
1
|
Refrigerant pressure switch connector
|
2
|
Refrigerant pressure switch
|
6. Install in the reverse order of removal.
7. Perform the refrigerant system performance test. (See REFRIGERANT SYSTEM PERFORMANCE TEST.)
Refrigerant Pressure Switch Installation Note
1. Apply compressor oil to O-ring and connect the joint.