DTC B266C [POWER LIFTGATE (PLG) SYSTEM]
id0902e9381500
DTC B266C |
Rotation sensor B circuit malfunction |
---|---|
DETECTION CONDITION
|
Rotation sensor B signal does not change
|
POSSIBLE CAUSE
|
• Open circuit in wiring harness between PLG control module terminal 2L and PLG drive unit terminal J
• Short to power supply in wiring harness between PLG control module terminal 2L and PLG drive unit terminal J
• Short to GND in wiring harness between PLG control module terminal 2L and PLG drive unit terminal J
• Rotation sensor malfunction
• PLG control module malfunction
|
![]() |
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT WIRING HARNESS BETWEEN PLG CONTROL UNIT AND PLG DRIVE UNIT
• Disconnect the PLG control module connector.
• Disconnect the PLG drive unit connector.
• Inspect the wiring harness between PLG control module terminal 2L and PLG drive unit terminal J for an open circuit/short circuit to the power supply system/short circuit to the ground system.
• Is the wiring harness normal?
|
Yes
|
Replace the PLG drive unit.
Go to the next step.
|
No
|
Repair or replace the wiring harness.
Go to the next step.
|
||
2
|
VERIFY CORRECTION COMPLETED
• Reconnect the disconnected connector.
• Clear the DTC.
• Operate the PLG system.
• Is DTC B266C stored?
|
Yes
|
Replace the PLG control module.
|
No
|
DTC troubleshooting completed.
|