THERMOSTAT INSPECTION [MZI-3.7]
id0112d3801300
1. Inspect the thermostat for the following.
Warning
• During inspection, the thermostat and water are extremely hot and can cause severe burns. Do not touch the thermostat and water.
• The valve should not open under normal temperature.
• Opening temperature and valve lift
― If there is a malfunction, replace the thermostat.
Thermostat initial-opening temperature
79.5—83.3 °C {175.2—181.9 °F}
Thermostat full-open temperature
94.5 °C {202.1 °F}
Thermostat full-open lift
More than 8.1 mm {0.32 in}