NONRETURN VALVE INSPECTION [MZI-3.7]


id0114d2803600

Warning
•  Fuel is very flammable liquid. If fuel spills or leaks from the pressurized fuel system, it will cause serious injury or death and facility breakage. Fuel can also irritate skin and eyes. To prevent this, always complete the “Fuel Line Safety Procedure”, while referring to the “BEFORE SERVICE PRECAUTION”.

1.  Follow “BEFORE SERVICE PRECAUTION” before performing any work operations to prevent fuel from spilling from the fuel system. (See BEFORE SERVICE PRECAUTION [MZI-3.7].)

2.  Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [MZI-3.7].)

3.  Disconnect the joint hose. (See FUEL TANK REMOVAL/INSTALLATION [MZI-3.7].)

4.  Remove the nonreturn valve. (See FUEL TANK REMOVAL/INSTALLATION [MZI-3.7].)

Note
•  The nonreturn valve is normally closed by the spring force.

5.  Verify that the nonreturn valve is closed.

•  If malfunction, replace the nonreturn valve. (See FUEL TANK REMOVAL/INSTALLATION [MZI-3.7].)
ac9wzw00000498

6.  Verify that the nonreturn valve is not stuck open and does not open even when pulled up by a finger.

•  If malfunction, replace the nonreturn valve. (See FUEL TANK REMOVAL/INSTALLATION [MZI-3.7].)