PCM CONFIGURATION [MZI-3.7]
id0140c3802600
1. Connect the M-MDS to DLC-2.
ac9uuw00001090
|
2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
3. Then, select the “Programmable Module Installation”, “PCM” from the screen menu.
4. Select “PCM” and perform procedures according to directions on the M-MDS screen.
5. Retrieve DTCs by the M-MDS, then verify that there is no DTC present.