AUTOMATIC TRANSAXLE FLUID (ATF) REPLACEMENT [AW6AX-EL]
id0517j6800600
1. Remove the oil dipstick.
2. Remove the oil drain plug and gasket.
ac9uuw00001946
|
3. Drain the ATF into a container.
4. Install a new gasket and the drain plug.
5. Add the specified ATF through the oil filler tube until it reaches the lower notch of dipstick.
6. Ensure that the ATF level is in the HOT range (65 °C {149 °F}).