ON-BOARD DIAGNOSTIC FUNCTION
id070200100300
Malfunction detection function
Fail-safe function
Fail-safe Function Table
Part where malfunction is determined |
Malfunction determined when IG SW at ON |
Malfunction already exists when IG SW turned to ON |
---|---|---|
Cabin temperature sensor
|
Cabin temperature sensor input value is fixed at 25 °C {77 °F}.
|
←
|
Ambient temperature sensor
|
Ambient temperature sensor input value is fixed at 15 °C {59 °F}.
|
←
|
Evaporator temperature sensor
|
Evaporator temperature sensor input value is fixed at 0 °C {32 °F}.
|
←
|
Solar radiation sensor
|
Solar radiation sensor value is fixed at 0 W/m2.
|
←
|
Engine coolant temperature sensor
|
Engine coolant temperature sensor input value is fixed at 80 °C {176 °F}.
|
←
|
Rear airflow volume control
(Rear control switch on)
|
Until a malfunction is detected, perform manual control using the normal value that was last detected. During malfunction determination, the rear airflow amount is controlled based on the rear target temperature calculated from the set temperature of the rear temperature setting dial.
|
←
|
Rear airflow temperature control
(Rear control switch on)
|
Until a malfunction is detected, perform control using the normal value that was last detected. During malfunction determination, the rear temperature setting is controlled at 22 °C {72 °F}
|
←
|
Air mix actuator
(potentiometer)
|
Air mix actuator drive signal is stopped right when the malfunction is determined.
|
• The actuators are driven as follows according to the voltage detected at the potentiometer circuit.
• If the potentiometer circuit voltage is between 0.1 to 4.9 V within 2 s from when the ignition switch is turned to the ON position, the actuator switches to the normal operation.
• If the actuator does not switch to the normal operation within 2 s, the actuator drive signal is stopped.
|
Airflow mode actuator
(potentiometer)
|
Airflow mode actuator drive signal is stopped right when the malfunction is determined.
|
• The actuators are driven as follows according to the voltage detected at the potentiometer circuit.
• If the potentiometer circuit voltage is between 0.1 to 4.9 V within 2 s from when the ignition switch is turned to the ON position, the actuator switches to the normal operation.
• If the actuator does not switch to the normal operation within 2 s, the actuator drive signal is stopped.
|
Air mix actuator
(motor lock)
|
Air mix actuator drive signal is stopped right when the malfunction is determined.
|
After the IG SW is at ON, the air mix actuator drive signal is again output normally.
|
Airflow mode actuator
(motor lock)
|
Airflow mode actuator drive signal is stopped right when the malfunction is determined.
|
After the IG SW is at ON, the airflow mode actuator drive signal is again output normally.
|
Memory Function
Display Function
Present Malfunction Display Mode
DTC Table
No. |
Output pattern |
Malfunction location |
Detected condition |
Memory function |
---|---|---|---|---|
02
|
![]() |
Solar radiation sensor (present malfunction)
|
Solar radiation sensor (RH) circuit short
|
—
|
04
|
![]() |
Solar radiation sensor (LH) circuit short
|
—
|
|
06
|
![]() |
Cabin temperature sensor (present malfunction)
|
Cabin temperature sensor circuit open/short circuit
|
—
|
10
|
![]() |
Front evaporator temperature sensor (present malfunction)
|
Front evaporator temperature sensor circuit open/short circuit
|
—
|
12
|
![]() |
Front ambient temperature sensor (present malfunction)
|
Front ambient temperature sensor circuit open/short circuit
|
—
|
18
|
![]() |
Driver-side front air mix actuator (potentiometer) (present malfunction)
|
Driver-side front air mix actuator (potentiometer) circuit open/short circuit
|
—
|
21
|
![]() |
Front airflow mode actuator (potentiometer) (present malfunction)
|
Front airflow mode actuator (potentiometer) circuit open/short circuit
|
—
|
37
|
![]() |
Passenger-side front air mix actuator (potentiometer) (present malfunction)
|
Passenger- side front air mix actuator (potentiometer) circuit open/short circuit
|
—
|
74
|
![]() |
Rear climate control unit set airflow volume communication system (present malfunction)
|
Between front climate control unit and rear climate control unit set airflow volume communication circuit open/short circuit
|
—
|
75
|
![]() |
Rear climate control unit set temperature communication system (present malfunction)
|
Between front climate control unit and rear climate control unit set temperature communication circuit open/short circuit
|
—
|
76
|
![]() |
Rear air mix actuator (potentiometer) (present malfunction)
|
Rear air mix actuator (potentiometer) circuit open/short circuit
|
—
|
78
|
![]() |
Rear evaporator temperature sensor (present malfunction)
|
Rear evaporator temperature sensor circuit open/short circuit
|
—
|
85
|
![]() |
Rear airflow mode actuator (potentiometer) (present malfunction)
|
Rear airflow mode actuator (potentiometer) circuit open/short circuit
|
—
|
Past Malfunction Display Mode
DTC Table
No. |
Output pattern |
Malfunction location |
Detected condition |
Memory function |
---|---|---|---|---|
07
|
![]() |
Cabin temperature sensor (past malfunction)
|
When an open/short has occurred in the cabin temperature sensor circuit 1 time or more in the past
|
X
|
11
|
![]() |
Front evaporator temperature sensor (past malfunction)
|
When an open/short has occurred in the front evaporator temperature sensor circuit 1 time or more in the past
|
X
|
13
|
![]() |
Ambient temperature sensor (past malfunction)
|
When an open/short has occurred in the ambient temperature sensor circuit 1 time or more in the past
|
X
|
19
|
![]() |
Driver-side front air mix actuator (potentiometer) (past malfunction)
|
When an open/short has occurred in the driver-side front air mix actuator (potentiometer) circuit 1 time or more in the past
|
X
|
22
|
![]() |
Front airflow mode actuator (potentiometer) (past malfunction)
|
When an open/short has occurred in the front airflow mode actuator (potentiometer) circuit 1 time or more in the past
|
X
|
38
|
![]() |
Passenger-side front air mix actuator (potentiometer) (past malfunction)
|
When an open/short has occurred in the passenger-side front air mix actuator (potentiometer) circuit 1 time or more in the past
|
X
|
58
|
![]() |
Driver-side front air mix actuator (motor lock) (past malfunction)
|
When motor lock has occurred in the driver-side front air mix actuator circuit 1 time or more in the past
|
X
|
59
|
![]() |
Front airflow mode actuator (motor lock) (past malfunction)
|
When motor lock has occurred in the front airflow mode actuator circuit 1 time or more in the past
|
X
|
61
|
![]() |
Passenger-side front air mix actuator (motor lock) (past malfunction)
|
When motor lock has occurred in the passenger-side front air mix actuator circuit 1 time or more in the past
|
X
|
77
|
![]() |
Rear air mix actuator (potentiometer) (past malfunction)
|
When an open/short has occurred in the rear air mix actuator (potentiometer) circuit 1 time or more in the past
|
X
|
79
|
![]() |
Rear evaporator temperature sensor (past malfunction)
|
When an open/short has occurred in the rear evaporator temperature sensor circuit 1 time or more in the past
|
X
|
86
|
![]() |
Rear airflow mode actuator (potentiometer) (past malfunction)
|
When an open/short has occurred in the rear airflow mode actuator (potentiometer) circuit 1 time or more in the past
|
X
|
95
|
![]() |
Rear air mix actuator (motor lock) (past malfunction)
|
When motor lock has occurred in the rear air mix actuator circuit 1 time or more in the past
|
X
|
96
|
![]() |
Rear airflow mode actuator (motor lock) (past malfunction)
|
When motor lock has occurred in the rear airflow mode actuator circuit 1 time or more in the past
|
X
|
A/C Operation Check Mode
Step |
Target part |
Operation condition |
Monitor display* |
---|---|---|---|
1
|
Front climate control unit
|
![]() |
Entire illumination of climate control display
|
Information display
|
![]() |
||
2
|
Blower motor
|
![]() |
01
|
3
|
Air mix door
|
![]() |
20.0 (0%)
20.5 (50%)
21.0 (100%)
20.5 (50%)
|
4
|
Airflow mode door
|
![]() |
03
|
5
|
Air intake door
A/C compressor
|
FRESH Û REC
ON Û OFF
|
04
|