REFRIGERANT SYSTEM SERVICE CAUTIONS
id071000800200
Handling Insufficient Refrigerant Level
• If an insufficient refrigerant level is detected at troubleshooting, do not charge (add) the refrigerant. Because an accurate amount of refrigerant cannot be determined from the pressure indicated on the manifold gauge, never charge the refrigerant. If there is too much or too little refrigerant from the refilling, there may be secondary problems such as damage to the refrigerant cycle parts, or a decrease of cooling performance. Therefore, if it is determined that the refrigerant level is insufficient, completely remove refrigerant from the refrigerant cycle and refill with refrigerant to the specified amount.
Handling A/C Related Parts
• There will be no effect on either performance or quality of A/C-related parts, including but not limited to the piping, etc., provided that said parts are serviced/repaired in accordance with standard procedure.
• When serviced/repaired A/C units in locations where there is a considerable risk of contamination from dirt or dust, plug up the openings on the parts to prevent dust/dirt from entering.
• When using adhesive material to cover openings on A/C parts, make sure that the adhesive side of the material does not come in contact with the connectors on the parts.
• When the system is opened to atmosphere, there is no need to replace the condenser, or the receiver dryer when it is housed within the condenser, provided that the unit is plugged accordingly.
Handling Compressor Oil
• Use only DENSO OIL8 compressor oil for this vehicle. Using a PAG oil other than DENSO OIL8 compressor oil can damage the A/C compressor.
• Do not spill DENSO OIL8 compressor oil on the vehicle. A drop of compressor oil on the vehicle surface can eat away at the paint. If oil gets on the vehicle, wipe it off immediately.
•
DENSO OIL8 compressor oil (PAG oil) has a higher moisture absorption efficiency than the previously used mineral oil. If moisture mixes with the compressor oil, the refrigerant system could be damaged. Therefore, install caps immediately after using the compressor oil or removing refrigerant system parts to prevent moisture absorption.