AIRFLOW TEMPERATURE CONTROL OPERATION


id074000102300


Airflow Temperature Automatic Control

•  The front climate control unit calculates the air mix actuator (front/rear) opening angle (airflow temperature) by adding the correction input from the ECT sensor and evaporator temperature sensor (front/rear) to the target temperature that was calculated based on the set temperature and input from each sensor, operating the actuator.
ac9uun00000228

Correction

MAX HOT and MAX COLD correction
•  When the temperature is set to 32.0, the air mix actuator (front/rear) opening angle is fixed at fully open and when set to 15.0, it is fixed at fully closed.
Air mix actuator opening angle correction
•  The climate control unit maintains the actuator at the opening angle calculated based on the position signal from the potentiometer inside the air mix actuator (front/rear).
ac9uun00000229