POWER LIFTGATE (PLG) CONTROL MODULE INSPECTION


id091100804300

1.  Measure the PLG control module terminal voltage.

2.  If there is large difference between the measured value and the value in the terminal voltage table, inspect the parts under “Inspection item(s)” and related wiring harnesses.

•  If the system does not work properly even though the inspection items or related wiring harnesses do not have any malfunction, replace the PLG control module.

Terminal Voltage Table (Reference)

ac9uuw00000855

Terminal

Signal name

Connected to

Measurement condition

Voltage (V)/Continuity

Inspection item(s)

1A
Closure motor (Closed)
Closure motor
After opening the liftgate, operate the closure motor with the liftgate half-closed
0 → B+→ 0
•  Liftgate latch and lock actuator
―  Latch position switch
―  Closure motor
1B
Closure motor (Open)
Closure motor
Open the fully closed liftgate by hand
0 → B+→ 0
•  Liftgate latch and lock actuator
―  Latch position switch
―  Closure motor
•  Liftgate outer handle switch
1C
Power supply
PLG 20 A fuse
Under any condition
B+
PLG 20 A fuse
1D
GND
Body ground
Under any condition
1.0 or less
•  Related wiring harnesses
1E
PLG motor (Open)
PLG motor
Open the fully closed liftgate
0 → B+→ 0
PLG drive unit
1F
PLG motor (Closed)
PLG motor
Close the fully opened liftgate
0 → B+→ 0
PLG drive unit
2A
IG1
METER 10 A fuse
Ignition switch is at ON position
B+
METER 10 A fuse
Ignition switch is at LOCK or ACC position
1.0 or less
2B
PLG rear switch signal
PLG rear switch
When operating the PLG rear switch
B+
PLG rear switch
When not operating the PLG rear switch
1.0 or less
2C
PLG buzzer output
PLG buzzer
When the PLG buzzer is sounding
B+
PLG buzzer
Other
1.0 or less
2D
PLG touch sensor GND
Body ground
Under any condition
1.0 or less
•  Related wiring harnesses
2G
Clutch output (-)
PLG clutch
When PLG is open or closing
1.0 or less
PLG drive unit
Other
No Continuity
2I
Clutch output (+)
PLG clutch
When PLG is open or closing
B+
PLG drive unit
Other
1.0 or less
2J
PLG motor rotation signal A
Rotation sensor
Pulse signal
-
PLG drive unit
2K
Rotation signal power source
Rotation sensor
Under any condition
5
PLG drive unit
2L
PLG motor rotation signal B
Rotation sensor
Pulse signal
-
PLG drive unit
2N
Rotation sensor GND
Body ground
Under any condition
1.0 or less
•  Related wiring harnesses
2O
Power supply
BCM
Under any condition
B+
BCM
3A
PLG touch sensor signal (RH)
PLG touch sensor (RH)
When sensor is operating normally (usually)
0.5—4.2 or less
PLG touch sensor (RH)
When sensor is at fault
Other than those above
3B
PLG touch sensor signal (LH)
PLG touch sensor (LH)
When sensor is operating normally (usually)
0.5—4.2 or less
PLG touch sensor (LH)
When sensor is at fault
Other than those above
3C
Lock signal
Passenger seat side lock link switch
Passenger seat side door is locked. Check the continuity with earth
Continuity
Passenger seat side lock link switch
Passenger seat side door is unlocked. Check the continuity with earth
No Continuity
3E
Motor return signal
Return switch
After opening the liftgate, operate the closure motor with the liftgate half-closed
1.0 or less
•  Liftgate latch and lock actuator
―  Return switch
3F
Liftgate latch switch signal
Liftgate latch switch
Liftgate is open (liftgate latch switch is ON)
1.0 or less
Liftgate latch and lock actuator
Liftgate is closed (liftgate latch switch is OFF)
B+
3G
Full latch switch
Latch position switch
After opening the liftgate, operate the closure motor with the liftgate half-closed
1.0 or less→ B+→ 1.0 or less
•  Liftgate latch and lock actuator
―  Latch position switch
―  Closure motor
3H
Half latch switch
Latch position switch
After opening the liftgate, operate the closure motor with the liftgate half-closed
1.0 or less→ B+
•  Liftgate latch and lock actuator
―  Latch position switch
―  Closure motor
3N*1
Unlock signal
Passenger seat side lock link switch
Passenger seat side door is locked. Check the continuity with earth
No Continuity
Passenger seat side lock link switch
Passenger seat side door is unlocked. Check the continuity with earth
Continuity
3O
Liftgate outer handle switch signal
Liftgate outer handle switch
When operating the liftgate outer handle (When the liftgate outer handle switch is ON)
B+
Liftgate outer handle switch
When not operating the liftgate outer handle (When the liftgate outer handle switch is OFF)
1.0 or less
3Q
PLG front switch signal (Input)
PLG front switch
PLG front switch: Switch is at ON
B+
PLG front switch
PLG front switch: Switch is at OFF
1.0 or less
3R
Power supply to PLG switches
PLG switch
PLG front switch: Open or close switch is at ON
1.0 or less
PLG control module
PLG front switch: Open or close switch is at OFF
B+
3U
CAN_L
-
Because this terminal is for communication, good/no good judgment by terminal voltage is not possible
-
3V
CAN_H
-
Because this terminal is for communication, good/no good judgment by terminal voltage is not possible
-

*1  :When checking the operation of UNLOCK signal, position the rear door lock knobs of both sides at LOCK.