FAN CONTROL MODULE INSPECTION [MZI-3.7]
id0112d3801100
1. Connect the M-MDS to the DLC-2.
ac9wzw00002171
|
2. Start and warm up the engine.
3. Monitor the engine coolant temperature with the M-MDS.
4. Measure the voltage between cooling fan motor connector (2 terminals) terminals A and B from the harness side as shown in the table.
ac9wzw00002172
|
Inspection |
Result |
||
---|---|---|---|
Condition |
A/C |
Engine coolant temp. |
|
IG SW ON or idling
|
OFF
|
Less than 96 °C {205 °F}
|
0 V (Fan stops.)
|
Idling
|
OFF
|
96—106 °C {205—223 °F}
|
4.11—10.29 V
|
Idling
|
ON*1
|
96—106 °C {205—223 °F}
|
Approx. 6.6 V
|
Idling
|
ON*2
|
96—106 °C {205—223 °F}
|
Approx. 7.5 V
|
Idling
|
OFF
|
More than 106 °C {223 °F}
|
B+
|
5. If all the above parts are normal, replace the fan control module.