THERMOSTAT INSPECTION [MZI-3.7]
id0112d3801300
1. Remove the thermostat. (See THERMOSTAT REMOVAL/INSTALLATION [MZI-3.7].)
2. Visually check that the thermostat valve is closed.
3. Place the thermostat in water.
-
Warning
-
• During inspection, the thermostat and water are extremely hot and can cause severe burns. Do not touch the thermostat and water.
4. Heat the water and check the following.
-
• Opening temperature and valve lift
-
-
Thermostat initial-opening temperature
-
79.5—83.3 °C {175.2—181.9 °F}
-
Thermostat full-open temperature
-
94.5 °C {202.1 °F}
-
Thermostat full-open lift
-
More than 8.1 mm {0.32 in}