AFTER SERVICE PRECAUTION [MZI-3.7]
id0114d2800400
Fuel Leakage Inspection
Using M-MDS
1. Connect the M-MDS to the DLC-2.
ac9wzw00002169
|
2. Using the simulation function “FP”, start the fuel pump. (See ON-BOARD DIAGNOSTIC TEST [MZI-3.7].)
3. Verify that there is no fuel leakage from the pressurized parts.
4. In the case of fuel leakage, replace the following components and then do the recheck by the fuel leakage checking procedure.
Without using M-MDS
1. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [MZI-3.7].)
2. Remove the fuel pump relay.
ac9wzw00001554
|
3. Using a jumper wire, short fuel pump relay terminals C and D in the main fuse block.
ac9wzw00002170
|
4. Connect the negative battery cable and operate the fuel pump. (See BATTERY REMOVAL/INSTALLATION [MZI-3.7].)
5. Verify that there is no fuel leakage from the pressurized parts.
6. In the case of fuel leakage, replace the following components and then do the recheck by the fuel leakage checking procedure.