REFRIGERANT PRESSURE SENSOR REMOVAL/INSTALLATION
id074000817300
1. Disconnect the negative battery cable.
2. Discharge the refrigerant. (See REFRIGERANT CHARGING.)
3. Disconnect the refrigerant pressure sensor connector.
4. Loosen the refrigerant pressure sensor using two spanners.
5. Remove the refrigerant pressure sensor. (See Refrigerant Pressure Sensor Installation Note.)
ac9wzw00002821
|
6. Install in the reverse order of removal.
7. Perform the refrigerant system performance test. (See REFRIGERANT SYSTEM PERFORMANCE TEST.)
Refrigerant Pressure Sensor Installation Note
1. Apply compressor oil to the O-rings and connect the joints.