DTC B118D:11 [BLIND SPOT MONITORING (BSM) CONTROL MODULE CONNECTOR 8-PIN TYPE]
id0902q2354700
Description |
Short to ground in BSM indicator light (RH) circuit |
---|---|
Detection condition
|
• The BSM control module (RH) monitors the BSM indicator light (RH) load current, while the BSM indicator light (RH) is operating. If the increase in the BSM indicator light (RH) load current is more than the specification, the BSM control module (RH) determines that the BSM indicator light (RH) has a short to ground.
|
Possible cause
|
• Power outer mirror (RH) connector or terminal malfunction
• BSM control module (RH) connector or terminal malfunction
• Short to ground in wiring harness between BSM control module (RH) terminal D and power outer mirror (RH) terminal D
• Power outer mirror (RH) malfunction
• BSM indicator light (RH) malfunction
• BSM control module (RH) malfunction
|
![]() |
Diagnostic procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
INSPECT POWER OUTER MIRROR (RH) CONNECTOR
• Turn the ignition switch to the OFF position.
• Disconnect the negative battery cable.
• Disconnect the power outer mirror (RH) connector.
• Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
• Is there any malfunction?
|
Yes
|
Repair or replace the connector, then go to Step 6.
|
No
|
Go to the next step.
|
||
2
|
INSPECT BSM CONTROL MODULE (RH) CONNECTOR
• Disconnect the BSM control module (RH) connector.
• Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
• Is there any malfunction?
|
Yes
|
Repair or replace the connector, then go to Step 6.
|
No
|
Go to the next step.
|
||
3
|
INSPECT BSM INDICATOR LIGHT (RH) CONTROL CIRCUIT FOR SHORT TO GROUND
• Verify that the power outer mirror (RH) and BSM control module (RH) connectors are disconnected.
• Inspect for continuity between power outer mirror (RH) terminal D (wiring harness-side) and body ground.
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness which has a short to ground, then go to Step 6.
|
No
|
Go to the next step.
|
||
4
|
INSPECT POWER OUTER MIRROR (RH)
• Inspect the power outer mirror (RH).
• Is there any malfunction?
|
Yes
|
Replace the power outer mirror (RH), then go to Step 6.
|
No
|
Go to the next step.
|
||
5
|
INSPECT BSM INDICATOR LIGHT (RH)
• Inspect the BSM indicator light (RH).
• Is there any malfunction?
|
Yes
|
Replace the outer mirror glass (RH), then go to the next step.
(See OUTER MIRROR GLASS REMOVAL.)
|
No
|
Go to the next step.
|
||
6
|
VERIFY DTC TROUBLESHOOTING COMPLETED
• Make sure to reconnect all disconnected connectors.
• Reconnect the negative battery cable.
• Clear the DTC for the BSM control module (RH) using the M-MDS.
• Retrieve the BSM control module (RH) DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Repeat the inspection from Step 1.
• If the malfunction recurs, replace the BSM control module (RH).
Go to the next step.
|
No
|
Go to the next step.
|
||
7
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|