No.3 DOOR GLASS DOES NOT OPERATE USING THE REQUEST SWITCH [POWER WINDOW SYSTEMS (EXTERIOR OPEN/CLOSE FUNCTION)]
id090361808800
3
|
Door glass does not operate using the request switch
|
POSSIBLE CAUSE
|
• Any door or liftgate is open.
• The ignition is switched to position other than off
• Keyless control module malfunction
• BCM malfunction
• Open circuit in wiring harness between request switch and keyless control module.
• Open circuit in wiring harness between keyless control module and BCM.
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
• Verify the door lock/unlock operation by operating the request switch.
• Does it operate normally?
|
Yes
|
Inspect the following parts, and repair or replace.
• Keyless control module
• BCM (See BODY CONTROL MODULE (BCM) INSPECTION.)
|
No
|
Go to the next step.
|
||
2
|
• Verify the open/close condition of the doors and the liftgate.
• Is the reason why they do not lock/unlock because a door or the liftgate is open?
|
Yes
|
The system is normal. (When any door or the liftgate is open, the system does not operate)
|
No
|
Go to the next step.
|
||
3
|
• Verify that the ignition is switched to a position other than off.
• Can the doors be locked/unlocked?
|
Yes
|
System is normal (Does not operation when the ignition is switched to position other than off.)
|
No
|
Go to the next step.
|
||
4
|
• The door lock/unlock does not operate for reasons other than Steps 2 and 3 above.
|
Yes
|
Inspect the following parts, and repair or replace.
• Keyless control module
• Wiring harness between the request switch and the keyless control module.
|
No
|
Reinspect for malfunction recurrence. If the malfunction is not corrected, repeat the procedure from Step 1.
|