No.7 ALL DOOR GLASS OPERATE ACCIDENTALLY [POWER WINDOW SYSTEMS (EXTERIOR OPEN/CLOSE FUNCTION)]
id090361809200
7
|
All door glasses operate accidentally
|
POSSIBLE CAUSE
|
• Transmitter malfunction
• Request switch malfunction
• Open or short circuit in wiring harness between request switch (each door) and keyless control module.
• Power window main switch malfunction
• Power window subswitch malfunction
• Open or short circuit in wiring harness between power window main switch and power window subswitch
• BCM malfunction
|
Diagnostic procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
• Inspect if malfunction is in operating by transmitter.
• Does it operate normally?
|
Yes
|
Inspect the transmitter.
|
No
|
Go to the next step.
|
||
2
|
• Inspect if malfunction is in operating by request switch.
• Does it operate normally?
|
Yes
|
Inspect the following parts and repair or replace.
• Request switch
• Wiring harness between request switch and keyless control module
|
No
|
Go to the next step.
|
||
3
|
• Inspect if malfunction is in operating power window main switch.
• Does it operate normally?
|
Yes
|
Inspect power window main switch
|
No
|
Go to the next step.
|
||
4
|
• Inspect if malfunction is in without operating Step1to 3.
|
Yes
|
Inspect the following parts and repair or replace
• Power window subswitch
• BCM (See BODY CONTROL MODULE (BCM) INSPECTION.)
• Wiring harness between power window subswitch and power window main switch
|
No
|
Reinspect for malfunction recurrence. If the malfunction is not corrected, repeat the procedure from Step 1.
|