No.2 DOES NOT OPERATE LIFTGATE AUTO CLOSURE [POWER LIFTGATE (PLG) SYSTEM]


id0903c9999700

2

Does not operate liftgate auto closure

DESCRIPTION
•  Liftgate is not pulled in from adjure position when the liftgate is closing.
POSSIBLE CAUSE
•  Malfunction in closer motor related part
―  Closer motor malfunction
―  Open circuit in wiring harness between closer motor and PLG control module
•  Malfunction in latch position switch related part
―  Half latch switch malfunction
―  Open or short to POWER/ground circuit in wiring harness between liftgate latch and lock actuator and PLG control module
•  PLG control module malfunction

When performing an asterisked (*) troubleshooting inspection, slightly shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, verify that the connectors, terminals and wiring harnesses are connected correctly and undamaged.

Diagnostic procedure

STEP

INSPECTION

ACTION

1
INSPECT CLOSER MOTOR
•  Inspect the closer motor.
•  Is the liftgate latch and lock actuator normal?
Yes
Go to the next step.
No
Replace the closer motor.
2*
INSPECT WIRING HARNESS BETWEEN PLG CONTROL MODULE AND CLOSER MOTOR
•  Turn the ignition switch to OFF position.
•  Disconnect the closer motor and PLG control module connectors.
•  Inspect for open or short to ground circuit for following:
―  Between closer motor terminal A and PLG control module terminal 1A
―  Between closer motor terminal B and PLG control module terminal 1B
•  Is open circuit detected?
Yes
Repair or replace malfunctioning part.
No
Go to the next step.
3
INSPECT HALF LATCH SWITCH
•  Inspect the half latch switch.
•  Is the half latch switch normal?
Yes
Go to the next step.
No
Replace the liftgate latch and lock actuator.
4*
INSPECT WIRING HARNESS BETWEEN PLG CONTROL MODULE AND HALF LATCH SWITCH
•  Turn the ignition switch to OFF position.
•  Disconnect the liftgate latch and lock actuator and PLG control module connectors.
•  Inspect for open or short to POWER/ground circuit between liftgate latch and lock actuator terminal B and PLG control module terminal 3H.
•  Is open or short circuit detected?
Yes
Repair or replace malfunctioning part.
No
Replace the PLG control module.