NO. 6 INSTRUMENT CLUSTER ILLUMINATION DOES NOT ILLUMINATE [INSTRUMENT CLUSTER]


id0903d5807900

6

Instrument cluster illumination does not illuminate

POSSIBLE CAUSE
•  Instrument cluster malfunction
•  Connector or pin malfunction
•  Fuse malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION

1
•  Turn the ignition switch to the ON position.
•  Turn the light switch to the TNS position.
•  Does the instrument cluster illumination turn on?
Yes
Troubleshooting completed.
No
Go to the next step.
2
•  Does the non-illumination include the entire instrument cluster?
Yes
Go to the next step.
No
Replace the instrument cluster.
3
•  Inspect the METER, ROOM and ILLUMI fuse.
•  Are the fuses normal?
Yes
Go to the next step.
No
Replace the fuse.
•  If the fuse is melted, inspect the wiring harness for short to ground. Repair or replace the wiring harness, then replace the fuse.
4
•  Turn the ignition switch to the OFF position.
•  Inspect the instrument cluster connector terminals for poor connection (such as damaged/pulled-out pins, and corrosion).
•  Are the terminals normal?
Yes
Replace the instrument cluster.
No
Repair or replace the terminal.