NO. 6 INSTRUMENT CLUSTER ILLUMINATION DOES NOT ILLUMINATE [INSTRUMENT CLUSTER]
id0903d5807900
6 |
Instrument cluster illumination does not illuminate |
---|---|
POSSIBLE CAUSE
|
• Instrument cluster malfunction
• Connector or pin malfunction
• Fuse malfunction
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Turn the ignition switch to the ON position.
• Turn the light switch to the TNS position.
• Does the instrument cluster illumination turn on?
|
Yes
|
Troubleshooting completed.
|
No
|
Go to the next step.
|
||
2
|
• Does the non-illumination include the entire instrument cluster?
|
Yes
|
Go to the next step.
|
No
|
Replace the instrument cluster.
|
||
3
|
• Inspect the METER, ROOM and ILLUMI fuse.
• Are the fuses normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the fuse.
• If the fuse is melted, inspect the wiring harness for short to ground. Repair or replace the wiring harness, then replace the fuse.
|
||
4
|
• Turn the ignition switch to the OFF position.
• Inspect the instrument cluster connector terminals for poor connection (such as damaged/pulled-out pins, and corrosion).
• Are the terminals normal?
|
Yes
|
Replace the instrument cluster.
|
No
|
Repair or replace the terminal.
|