POWER LIFTGATE (PLG) CONTROL MODULE CONSTRUCTION/OPERATION
id091100104500
Fail-safe Function
Item
|
Detection Condition
|
Action after detection
|
Auto operation return
|
Rotation sensor malfunction
|
• Pulse signal A fixed at high or low is detected
• Pulse signal B fixed at high or low is detected
• Abnormal pulse count detected
• Reverse direction pulse detected for operation direction
|
Auto operation stop (Clutch off)
|
Liftgate closed
|
Damper damage
|
After auto open operation or emergency stop (Clutch off), a sudden pulse in the close direction is detected
|
Auto close operation
|
Liftgate closed
|
PLG motor over-current
|
Over-current in PLG motor
|
Auto operation stop (Clutch off)
|
Liftgate closed or open
|
Continuous reverse
|
• Switch is operated continuously
• Continuous obstruction detected
|
Auto operation stop (Clutch off)
|
Liftgate closed or open
|
PLG motor failure
|
PLG motor GND fault detection
|
Auto operation stop (Clutch off)
|
Liftgate fully closed
|
ECU failure
|
PLG motor FET ON fault detection
|
Auto operation stop (Clutch off)
|
Liftgate fully closed
|