KEYLESS RECEIVER INSPECTION [KEYLESS ENTRY SYSTEM]


id0914008076b3

1.  Measure the voltage at the auto light/wiper control module terminals as indicated below.


Terminal Voltage Table (Reference)

ac9wzw00001075

Terminal

Signal name

Connected to

Measured condition

Voltage (V)

Inspection item(s)

A
Power supply
BCM
Under any condition
B+
•  ROOM 15 A fuse
•  BCM
•  Related wiring harnesses
D
Serial communication
BCM
Because this terminal is for communication, good/no good judgment by terminal voltage is not possible.
•  BCM
•  Related wiring harnesses
E
GND
Body ground
Under any condition.
1.0 or less
Related wiring harnesses