SLIDING SUNROOF OPERATION
id091500100500
Item |
Detection conditions |
Fail-safe status |
Cancel condition |
|
---|---|---|---|---|
Motor is stopped |
Motor is operating |
|||
Obstruction detection
|
Obstruction load of 100 N {10.2 kgf·m,73.8 ft·lbf} or more
|
—
|
Reverse operation
• Reverses to the full-tilt position when detected during tilt-down operation.
• Moves 200 mm {7.87 in} in the open direction (to fully open position if sunroof opens within 200 mm {7.87 in}) when detected during slide-close operation.
|
Reverse operation completed
|
Low voltage detection
|
Approx. 8 V or less voltage detected
|
Operation prohibited
|
Operation continued
|
Voltage is within the guaranteed operation voltage
|
Over-voltage detection
|
Approx. 18 V or more voltage detected
|
Operation prohibited
|
Operation stopped → Operation prohibited
|
Voltage is within the guaranteed operation voltage
|
Pulse sensor error
|
One side of the pulse cannot be detected
|
—
|
Operation stopped
Switches to the starting point, non-set conditions
|
Sensor signal returned to normal
|
Improper roof position
|
Pulse sensor output is at the overflow value or more, or at the underflow value or less (Only occurs when the glass is moved forcibly to the full-tilt position or to the position exceeding the full-open position.)
|
Switches to the starting point, non-set conditions
|
—
|
Initialization of the roof position completed
|
EEPROM error
|
Reading error of the roof position data preset in the EEPROM when the operation is started
|
Operation prohibited
|
—
|
EEPROM is read normally
|
Microcomputer overdrive
|
Watchdog timer clear signal does not input from the microcomputer
|
Operation prohibited
|
Operation stopped → Operation prohibited
|
Normal operation is started after the microcomputer power-on reset
|
Element breakage affecting closing operation
|
—
|
Operation prohibited
|
Operation stopped → Operation prohibited
|
Does not recover from operation prohibition
|