FOW/LDWS SWITCH INSPECTION


id092200035200

1.  Disconnect the negative battery cable.

2.  Remove the FOW/LDWS switch. (See FOW/LDWS SWITCH REMOVAL/INSTALLATION.)

3.  Verify that the continuity is as indicated in the table.

ac9wzw00002631

•  If not as indicated in the table, replace the cluster switch.

4.  Apply battery positive voltage to FOW/LDWS switch terminal E, and connect terminal A to ground.

ac9wzw00002682

5.  Verify that the LED illuminates.

•  If there is any malfunction, replace the cluster switch.