INSTRUMENT CLUSTER INSPECTION


id092200800400


Speedometer


Using the input/output check mode

1.  Inspect the speedometer by setting it to check code 12 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)


Using a speedometer tester

1.  Adjust the tire pressure to the specification.

2.  Using a speedometer tester, verify that the tester reading is as indicated in the table below.

Speedometer tester indication (km/h)

Allowable range (km/h)

20
20—26
40
40—45
60
61—66
80
81—87
100
101—108
120
122—129
140
142—150

3.  Verify that the speedometer reading is within the range indicated in the table.

•  If the speedometer does not move or the indication is not within the allowable range, inspect the PCM, TCM and related wiring harnesses.
―  If the PCM, TCM and related wiring harnesses are normal, replace the instrument cluster.


Tachometer


Using the input/output check mode

1.  Inspect the tachometer by setting it to check code 13 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)


Using M-MDS

Caution
•  If the engine speed exceeds the allowable range, the engine could be damaged. Therefore, when inspecting the tachometer, do not allow the engine speed to exceed the allowable range indication on the tachometer.

1.  Connect the M-MDS to the DLC-2.

ac9uuw00000571

2.  After the vehicle is identified, select the following items from the initialization screen of the M-MDS.

•  When using the IDS (laptop PC)
1.  Select “DataLogger”.
2.  Select “Modules”.
3.  Select “IC”.
•  When using the PDS (Pocket PC)
1.  Select “Module Tests”.
2.  Select “IC”.
3.  Select “DataLogger”.

3.  Compare the data monitor item (IC_TACHO) with the tachometer indication.

•  If the speedometer does not move or the indication is not within the allowable range, inspect the related wiring harnesses.
―  If the related wiring harnesses are normal, replace the instrument cluster.


Fuel gauge

1.  Inspect the fuel gauge by setting it to check code 23 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)


Water temperature gauge

1.  Inspect the water temperature gauge by setting it to check code 25 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)