PID/DATA MONITOR TABLE [HEAT PUMP CONTROL UNIT]
id0702l5717500
PID |
Unit/Operation |
Data contents |
Module control terminal |
---|---|---|---|
E_COMP_IN_REFR_TEMP
|
°C, °F
|
Displays the condenser outlet temperature detected by the temperature sensor of refrigerant line for condenser outlet.
|
S
|
EVA_OUT_REFR_TEMP
|
°C, °F
|
Displays the evaporator outlet temperature detected by the temperature sensor of refrigerant line for evaporator outlet.
|
U
|
2_WAY_VLV
|
off/on
|
• OFF: 2way valve for refrigerant is off
• ON: 2way valve for refrigerant is on
|
I
|
3_WAY_VLV
|
off/on
|
• OFF: 3way valve for refrigerant is off
• ON: 3way valve for refrigerant is on
|
K
|
E_COMP_RUN-IN_STAT
|
Not_completed/Completed
|
• Not_completed: Electric compressor run-in is not completed
• Completed: Electric compressor run-in is completed
|
—
|
A/C_EEV_INIT_LRN
|
off/on
|
• OFF: Electric expansion valve is off
• ON: Electric expansion valve is on
|
AD,Z,AF,AB
|
VPWR
|
V
|
Displays the power supply voltage to the dash-electrical supply unit.
|
—
|