2WAY VALVE FOR REFRIGERANT [FULL-AUTO AIR CONDITIONER]
id0740a1700200
Purpose
Function
Structure/construction
a30jjn00000412
|
Operation
When heating
a30jjn00000413
|
1. When the coil is turned on (energized), the plunger is pulled downward.
(Plunger spring load is less than solenoid coil attraction)
2. The main valve is pushed downward and closes by the force of the plunger.
(Main valve spring load is less than plunger downward force)
3. The refrigerant does not pass through the 2way valve for refrigerant and flows towards the orifice when the main valve is closed.
When cooling
aatjjn00003222
|
1. When the coil is turned off (de-energized), the plunger moves upward by the force of the plunger spring.
(Plunger spring force is greater than solenoid coil attraction)
2. The main valve is pushed upward and opens by the force of the main valve spring.
(Main valve spring is greater than plunger downward force)
3. The refrigerant passes through the 2way valve for refrigerant and flows towards the condenser when the main valve is open.