PID/DATA MONITOR TABLE [AUTO LEVELING CONTROL MODULE (E)]
id09027b120500
PID |
Unit/Operation |
Data contents |
Module control terminal |
---|---|---|---|
ACC_SEN_TEMP
|
°C, °F
|
Displays acceleration sensor temperature.
|
—
|
ACC_SEN_TEMP_INIT
|
°C, °F
|
Displays acceleration sensor temperature when auto leveling control module is initialized.
|
—
|
ACC_X
|
mG
|
Displays current acceleration value (X-axis).
|
—
|
ACC_X_INIT
|
mG
|
Displays acceleration value (X-axis) when auto leveling control module is initialized.
|
—
|
ACC_Y
|
mG
|
Displays current acceleration value (Y-axis).
|
—
|
ACC_Y_INIT
|
mG
|
Displays acceleration value (Y-axis) when auto leveling control module is initialized.
|
—
|
ACC_Z
|
mG
|
Displays current acceleration value (Z-axis).
|
—
|
ACC_Z_INIT
|
mG
|
Displays acceleration value (X-axis) when auto leveling control module is initialized.
|
—
|
H/L_STAT
|
OFF/DRL ON/TNS ON/HeadlightLo ON/HeadlightHi ON
|
• OFF: Headlights are not illuminated.
• DRL ON: Daytime running light (DRL) is illuminated.
• TNS ON: Parking light is illuminated.
• HeadlightLo ON: Headlight LO are illuminated.
• HeadlightHi: Headlight HI are illuminated.
|
E, H
|
HORZ_STAT
|
Not horizontally/horizontally
|
Displays status of horizontal.
|
—
|
LVL_TGT_ANG
|
° (deg)
|
Displays target angle of leveling control.
|
D
|
PITCH
|
° (deg)
|
Displays calculated pitch angle.
|
—
|
PITCH_INIT
|
° (deg)
|
Displays calculated pitch angle when auto leveling control module is initialized.
|
—
|
VPWR
|
V
|
Displays auto leveling control module power supply voltage.
|
J
|
VSS
|
km/h, mph
|
Vehicle speed is displayed.
|
E, H
|