THEFT-DETERRENT HORN INSPECTION [(E)]


id0914007022x2

1.  Disconnect the negative lead-acid battery terminal. (See NEGATIVE LEAD-ACID BATTERY TERMINAL DISCONNECTION/CONNECTION.)

2.  Remove the theft-deterrent horn. (See THEFT-DETERRENT HORN REMOVAL/INSTALLATION [(E)].)

3.  Apply lead-acid battery positive voltage to horn terminal A, and connect the horn retaining bolt to ground as shown in the figure, and then verify that the horn sounds.

ac30zw00003246

•  If the horn does not sound, replace the horn. (See THEFT-DETERRENT HORN REMOVAL/INSTALLATION [(E)].)