FRONT ACCESSORY SOCKET INSPECTION


id092100701600

1.  Disconnect the negative lead-acid battery terminal. (See NEGATIVE LEAD-ACID BATTERY TERMINAL DISCONNECTION/CONNECTION.)

2.  Remove the front accessory socket. (See FRONT ACCESSORY SOCKET REMOVAL/INSTALLATION.)

3.  Connect the tester probe to the position shown in the figure and verify that there is continuity.

a30zzw00000957
a30zzw00000958

•  If it cannot be verified, replace the front accessory socket. (See FRONT ACCESSORY SOCKET REMOVAL/INSTALLATION.)