PID/DATA MONITOR TABLE [PCM (e-SKYACTIV (E))]
id300202042614
PID/data monitor item |
Unit/Condition |
Definition |
PCM terminal |
---|---|---|---|
12V_BATT_CHARGE_MODE
|
OFF/ON
|
• Lead-acid battery charging mode
|
—
|
A/C_PRES_BEF_EXP_VLV
|
kPa {MPa}, mBar {Bar}, psi, in H20
|
• Displays refrigerant pressure input from refrigerant pressure sensor.
|
S
|
A/C_PRES_BEF_EXP_VLV
|
V
|
• Displays refrigerant pressure sensor voltage.
|
S
|
A/C_REQ
|
No(False)/Yes(True)
|
• Displays A/C switch status received by PCM via CAN.
|
CAN (AK, AL)
|
A/C_SW
|
Off/On
|
• Displays A/C relay status input from A/C relay.
|
CG
|
AC_CHG_POWER
|
kW
|
• Displays electric power during normal charging.
|
—
|
AIRSHUT_CAL_STAT
|
Grille Shutter Module "A" Is Not Calibrated / Grille Shutter Module "A" Is Half Calibrated In Direction Open / Grille Shutter Module "A" Is Half Calibrated In Direction Closed / Grille Shutter Module "A" Is Fully Calibrated
|
• Displays active air shutter fully open/closed position learning status.
|
BU
|
AIRSHUT_POS_ACT
|
% Open
|
• Displays active air shutter position.
|
BU
|
AIRSHUT_POS_COMD
|
% Open
|
• Displays active air shutter operation status.
|
BU
|
AMB_AIR_TEMP_RAW
|
°C, °F
|
• Displays actually measured ambient temperature input from ambient temperature sensor.
|
AE
|
APP_MODE
|
Accelerator Pedal Is Partially Depressed / Accelertor Pedal Is Fully Depressed / Accelerator Pedal Is Not Depressed
|
• Displays accelerator pedal depression status.
|
—
|
APP_RELAT
|
%
|
• Displays accelerator pedal opening angle (relative value) with the fully released status as 0% and fully depressed status as 100%.
|
—
|
APP1
|
%
|
• Displays accelerator pedal opening angle (absolute value) input from APP sensor No.1.
|
G
|
APP1
|
V
|
• Displays APP sensor No.1 voltage.
|
|
APP2
|
%
|
• Displays accelerator pedal opening angle (absolute value) input from APP sensor No.2.
|
E
|
APP2
|
V
|
• Displays APP sensor No.2 voltage.
|
|
AUTO_P_GET_OFF
|
times
|
• Displays number of times Auto P function (in conjunction with getting out of vehicle) operates.
|
—
|
AUTO_P_IG_OFF
|
times
|
• Displays number of times Auto P function (in conjunction with main power switched OFF) operates.
|
—
|
BARO
|
kPa {MPa}, mBar {Bar}, psi, in H20
|
• Displays actually measured barometric pressure input from BARO sensor built into PCM.
|
—
|
BATT_CUR
|
Amp
|
• Displays lead-acid battery charge/discharge current.
|
—
|
BATT_DAY
|
Day
|
• Displays number of days elapsed since current sensor initialization.
|
—
|
BATT_RES
|
mOhm
|
• Displays lead-acid battery internal resistance (estimated).
|
—
|
BATT_SOC
|
%
|
• Displays lead-acid battery charge condition (estimated).
|
—
|
BATT_TEMP
|
°C, °F
|
• Displays lead-acid battery temperature.
|
—
|
BATT_VOLT
|
V
|
• Displays lead-acid battery voltage.
|
—
|
BRK_FLD_PRES
|
kPa {MPa}, mBar {Bar}, psi, in H20
|
• Displays actually measured brake fluid pressure input from brake fluid pressure sensor built into electronically controlled brake unit via CAN.
|
CAN (AW, AX)
|
BRK_PEDAL_POS
|
mm
|
• Displays brake pedal depression amount.
|
CAN (AW, AX)
|
CHARGE_MODE
|
OFF/ON
|
• Displays normal charging mode operation status.
|
—
|
CHG_CABLE_CONNECT
|
OFF/ON
|
• Displays AC charging cable connection status.
|
—
|
CHG_STAT_IND
|
OFF/ON
|
• Displays charging indicator on status.
|
CAN (BC, BD)
|
CLR_DTC_DIST
|
km, ft, mi
|
• Displays distance after DTC cleared.
|
—
|
CLTCH_CUT_SW
|
OFF/ON
|
• Displays in the M-MDS but it does not operate.
|
—
|
CONNECTOR_LCK_ACTAT_REQ
|
OFF/ON
|
• Displays charging connector lock request status.
|
CAN (BC, BD)
|
DC_CHG_CUR_COMBO
|
A
|
• Displays current value input from charging equipment during quick charging.
|
CAN (BC, BD)
|
DC_CHARGE_MODE
|
A
|
• Displays quick charging mode operation status.
|
—
|
DC_CHG_CABLE_CONNECT
|
OFF/ON
|
• Displays onboard charging cable connection status.
|
—
|
DC_CHG_CUR_CHADEMO
|
A
|
• Displays in the M-MDS but it does not operate.
|
—
|
DC_CHG_IN_VOLT_STAT
|
OFF/ON
|
• Displays whether or not voltage is applied to charge lid box assembly.
|
—
|
DC_CHG_STAT_CHADEMO
|
InitialState / ConnectorDetection / Handshaking / ConnectorLock / Charging / Stop / WeldingDetection / Discharge / CANStop
|
• Displays in the M-MDS but it does not operate.
|
—
|
DC_CHG_STAT_COMBO
|
Initial_state / Establish IP-based Connection / supportedAppProtocol / SessionSetup / ServiceDiscovery / ServiceDetail / PaymentServiceSelection / PaymentDetails / Authorization / ChargeParameterDiscovery / CableCheck / PreCharge / PowerDelivery_Start / CertificateUpdate / CertificateInstallation / MeteringReceipt / CurrentDemand / PowerDelivery_End / ChargingStatus / WeldingDetection / SessionStop / Error / Sleep
|
• Displays charging status from charge port (COMBO CCS Type2).
|
CAN (BC, BD)
|
DRIVE_MODE
|
OFF/ON
|
• Displays drive mode operation status.
|
—
|
DRIVE_SYS_WAKEUP_FAIL
|
OFF/ON
|
• Displays whether or not there is a cause for the EV system not starting.
|
—
|
E_POWER_SUPPLY_MODE
|
OFF/ON
|
• Displays power supply mode operation status.
|
—
|
E_WATER_PUMP_ACTL
|
%
|
• Displays electric water pump motor rotation speed.
|
BP
|
E_WATER_TEMP
|
°C, °F
|
• Displays coolant temperature.
|
P
|
FAN
|
%
|
• Displays the fan control module control duty value
|
BZ
|
GEAR
|
Unknown / Forward Drive 1 / Forward Drive 2 / Forward Drive 3 / Forward Drive 4 / Forward Drive 5 / Forward Drive 6 / Forward Drive 7 / Forward Drive 8 / Not In Park / Park/Neutral / Drive / Reverse
|
• Displays gear commanded.
|
AW, AX
|
GEN_VOLT_COMD
|
V
|
• Displays in the M-MDS but it does not operate.
|
—
|
H_SPD_FAN
|
Off/On
|
• Displays the cooling fan (high speed range) control status.
|
BZ
|
HEAT_CTRL_PNL_A/C_MODE
|
OFF/ON
|
• Displays climate control unit operation A/C mode operation status.
|
—
|
HV_BATT_AFT_COOLING_MODE
|
OFF/ON
|
• Displays high voltage battery after-cooling mode operation status.
|
—
|
HV_BATT_COOLING_MODE
|
OFF/ON
|
• Displays high voltage battery cooling mode operation status.
|
—
|
HV_BATT_DEFROSTING_MODE
|
OFF/ON
|
• Displays high voltage battery defroster mode operation status.
|
—
|
HV_BATT_WARM_UP_DC_MODE
|
OFF/ON
|
• Displays high voltage battery warm-up mode operation status. (During quick charging)
|
—
|
HV_BATT_WARM_UP_MODE
|
OFF/ON
|
• Displays high voltage battery warm-up mode operation status.
|
—
|
INGEAR
|
False/True
|
• Displays gears are engaged.
|
—
|
I-STOP_D_SW
|
OFF/ON
|
• Displays in the M-MDS but it does not operate.
|
—
|
I-STOP_N_SW
|
OFF/ON
|
—
|
|
I-STOP_OFF_SW
|
OFF/ON
|
—
|
|
I-STOP_VEH_STOP
|
OFF/ON
|
—
|
|
I-STOP_VSPD_HIST
|
OFF/ON
|
—
|
|
KEEP_CHARGE_MODE
|
OFF/ON
|
• Displays keep charging mode operation status.
|
—
|
L_SPD_FAN
|
Off/On
|
• Displays the cooling fan (low speed range) control status.
|
BZ
|
LID_LCK_ACTAT_ACTL
|
OFF/ON
|
• Displays charge port lid lock request status.
|
CAN (BC, BD)
|
LID_LCK_ACTAT_REQ
|
OFF/ON
|
• Displays charge port lid lock status.
|
CAN (BC, BD)
|
M_SPD_FAN
|
Off/On
|
• Displays the cooling fan (middle speed range) control status.
|
BZ
|
MANUAL_GEAR_POS
|
Neutral / First gear / Second gear / Third gear / Fourth gear / Fifth gear / Sixth gear / Reverse gear / Undefined gear / Not used / No sensor fitted (i.e. auto) / Gear shift in progress / Y sensor fault, transmission in neutral / Y sensor fault, transmission in undefined gear / Y sensor fault, gear change in progess / Error state
|
• Displays in the M-MDS but it does not operate.
|
—
|
MIL
|
Off/On
|
• Displays in the M-MDS but it does not operate.
|
—
|
MIL_DIST
|
km, ft, mi
|
—
|
|
MISS_SHIFT_D_RUNNING
|
times
|
• Displays number of times user shifts selector lever to D position while reversing at speed of 5 km/h {3 mph} or more.
|
—
|
MISS_SHIFT_N_RUNNING
|
times
|
• Displays number of times user shifts selector lever to N position while driving at speed of 5 km/h {3 mph} or more.
|
—
|
MISS_SHIFT_P_MOVING
|
times
|
• Displays number of times user shifts selector lever to P position until vehicle is stopped completely (while driving at speed of 1 km/h {0.6 mph} or less).
|
—
|
MISS_SHIFT_P_RUNNING
|
times
|
• Displays number of times user shifts selector lever to P position while driving at speed of 5 km/h {3 mph} or more.
|
—
|
MISS_SHIFT_R_RUNNING
|
times
|
• Displays number of times user shifts selector lever to R position while driving forward at speed of 5 km/h {3 mph} or more.
|
—
|
MOTOR_TRQ_REQ
|
Nm
|
• Displays electric motor torque value requested to drive motor control module.
|
CAN (AQ, AR)
|
N-D_N-R_WHILE_ACCEL_PRESS
|
times
|
• Displays the number of times selector lever is shifted from N position to D or R position while depressing accelerator pedal.
|
—
|
OIL_PRES_SOL
|
OFF/ON
|
• Displays in the M-MDS but it does not operate.
|
—
|
PCM_WAKEUP_MODE
|
OFF/ON
|
• Displays PCM start mode operation status.
|
—
|
PORT_LAMP_REQ
|
OFF/ON
|
• Displays charge port illumination on request status.
|
CAN (BC, BD)
|
REMOTE_A/C_MODE
|
OFF/ON
|
• Displays remote climate control mode operation status.
|
—
|
REMOTE_CHARGE_MODE
|
OFF/ON
|
• Displays remote charging mode operation status.
|
—
|
REV_SW
|
False/True
|
• Displays in the M-MDS but it does not operate.
|
—
|
REX_MODE
|
OFF/ON
|
• Displays in the M-MDS but it does not operate.
|
—
|
TIMER_A/C_MODE
|
OFF/ON
|
• Displays climate control timer mode operation status.
|
—
|
TIMER_CHARGE_MODE
|
OFF/ON
|
• Displays charging timer mode operation status.
|
—
|
VPWR
|
V
|
• Displays lead-acid battery positive voltage.
|
CY
|
VSS
|
KPH, MPH
|
• Displays vehicle speed.
|
CAN (AK, AL)
|
WSPD_L/F
|
KPH, MPH
|
• Displays rotation speed of wheel (LF).
|
CAN (AK, AL)
|
WSPD_L/R
|
KPH, MPH
|
• Displays rotation speed of wheel (RF).
|
CAN (AK, AL)
|
WSPD_R/F
|
KPH, MPH
|
• Displays rotation speed of wheel (LR).
|
CAN (AK, AL)
|
WSPD_R/R
|
KPH, MPH
|
• Displays rotation speed of wheel (RR).
|
CAN (AK, AL)
|