CURRENT SENSOR
id304000202500
Purpose/Function
• The lead-acid battery conditions are monitored as basic information for determining the generator output current.
• The lead-acid battery condition is input to the PCM via LIN communication.
Construction
• Installed to the negative lead-acid battery cable.
• The current sensor has adopted shunt resistance on the detection area and a thermistor for detecting the lead-acid battery condition.
Operation
• The battery charge/discharge flow, lead-acid battery voltage, and the lead-acid battery terminal temperature are input to the PCM by LIN communication.