CURRENT SENSOR


id304000202500


Purpose/Function

•  The lead-acid battery conditions are monitored as basic information for determining the generator output current.
•  The lead-acid battery condition is input to the PCM via LIN communication.

Construction

•  Installed to the negative lead-acid battery cable.
am3zzn00008559
•  The current sensor has adopted shunt resistance on the detection area and a thermistor for detecting the lead-acid battery condition.

Operation

•  The battery charge/discharge flow, lead-acid battery voltage, and the lead-acid battery terminal temperature are input to the PCM by LIN communication.
a30zzn00000969