FUEL PUMP UNIT INSPECTION [SKYACTIV-G 2.0]
id0114z5087200
Fuel Pump Operation Inspection
1. Connect the M-MDS to the DLC-2.
2. Perform the KOEO self-test. (See DTC INSPECTION.)
-
• If a DTC is detected, repair the malfunctioning location according to the applicable DTC troubleshooting. (See
DTC TABLE [PCM (SKYACTIV-G)].)
3. Remove the fuel-filler cap.
4. Switch the ignition ON (engine off).
5. Verify the following operation sounds for approx. 1 s after the ignition is switched ON (engine off).
-
• Fuel pump (Verify direct operation sound from fuel-filler opening)
-
― If the operation sounds cannot be verified, inspect the following and repair or replace the malfunctioning location.
Fuel pump relay operation sound cannot be verified
• Fuel pump relay (stuck open/closed)
• Wiring harness between IG1 relay and fuel pump relay terminal A (short, open circuit)
• Wiring harness between fuel pump relay terminal E and PCM terminal 2AW (short, open circuit)
Fuel pump operation sound cannot be verified
• Fuel pump relay (stuck open or open circuit in internal circuit)
• Wiring harness between battery and fuel pump relay terminal D (short, open circuit)
• Wiring harness between fuel pump relay terminal C and fuel pump control module terminal 2B (short, open circuit)
• Wiring harness between fuel pump unit terminal A and fuel pump control module terminal 2C (short, open circuit)
• Wiring harness between fuel pump unit terminal D and fuel pump control module terminal 2E (short, open circuit)
• Wiring harness between fuel pump unit terminal E and fuel pump control module terminal 2F (short, open circuit)
• Wiring harness between fuel pump unit terminal B and fuel pump control module terminal 2A (short, open circuit)
• Wiring harness between fuel pump control module terminal 2D and body ground (open circuit, ground point looseness or lifting)
-
― If a malfunction can be verified, repair the malfunctioning location and perform Step 5 again.
Continuity Inspection
1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Disconnect the fuel pump unit connector. (See FUEL PUMP UNIT REMOVAL/INSTALLATION [SKYACTIV-G 2.0].)
3. Inspect for continuity at the following terminals:
-
• fuel pump unit terminal A—fuel pump unit terminal D.
• fuel pump unit terminal D—fuel pump unit terminal E.
• fuel pump unit terminal E—fuel pump unit terminal A.
-
• If there is continuity, the fuel pump unit is normal therefore the inspection is completed.