IMMOBILIZER SYSTEM-RELATED PARTS PROGRAMMING
id091400203000
1. Shift the selector lever to the P position.
2. Operate the parking brake.
3. Connect the M-MDS to the DLC-2.
4. Switch the ignition ON (engine off).
5. Activate the M-MDS and perform the following procedure.
6. Select the following items according to the maintenance contents.
M-MDS display |
Service content |
Items to be prepared |
|
---|---|---|---|
Additional advanced key
|
Select when programming an additional advanced key with the immobilizer system operating normally (ignition can be switched ON (engine on)).
|
Valid remote transmitter
|
![]() |
Remote transmitters to program
|
![]() |
||
Deleting and programming advanced keys
|
Select when replacing an advanced key if the key was lost.
|
Remote transmitters to program
|
![]() |
![]() |
|||
Replacing immobilizer-related modules
|
Select when replacing an immobilizer-related module (body control module (BCM)/LF control unit/PCM/steering lock unit).
|
Remote transmitters to program
|
![]() |
![]() |
7. Perform immobilizer system-related part programming according to the directions on the M-MDS.
8. Touch the push button start with the emblem side of the remote transmitter and verify that the engine starts.
a30zzw00006413
|
9. Verify that the engine starts while the remote transmitter is not in contact with the push button start.
10. Verify that no DTC is displayed. (See DTC INSPECTION.)
11. If servicing is performed after turning off (disabling) the pacemaker radio wave interference prevention function and the power saving function of the remote transmitter, turn on (enable) the functions.