FUEL-FILLER LID LOCK ACTUATOR INSPECTION
id091400204800
1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Disconnect the fuel-filler lid lock actuator connector. (See FUEL-FILLER LID LOCK ACTUATOR REMOVAL/INSTALLATION.)
3. Apply battery positive voltage and connect the ground to the fuel-filler lid lock actuator terminals as indicated in the table below and verify the operation condition.
a30zzw00006086
|
B+ terminal |
Ground terminal |
Operation |
---|---|---|
A
|
B
|
Unlock
|
B
|
A
|
Lock
|