STEP
|
INSPECTION
|
ACTION
|
1
|
INSPECT FOR MALFUNCTION IN KEYLESS UNIT POWER SUPPLY CIRCUIT OR ELSEWHERE
• Did any of the following operate during the malfunction diagnosis?
-
- All doors lock/unlock.
-
- Hazard warning light flashes.
|
Yes
|
Go to the next step.
|
No
|
Inspect the connection of the keyless control module connectors, and then go to Step 4.
|
2
|
INSPECT FOR MALFUNCTION IN KEYLESS SWITCH OR ELSEWHERE
• Did the following operate during the malfunction diagnosis?
-
- All doors lock/unlock.
|
Yes
|
Go to the next step.
|
No
|
Go to step 7.
|
3
|
INSPECT FOR MALFUNCTION IN DOOR LOCK ACTUATOR OR ELSEWHERE
• Did the following operate during the malfunction diagnosis?
-
- Hazard warning light flashes.
|
Yes
|
Go to the next step.
|
No
|
Go to step 8.
|
4
|
INSPECT KEYLESS UNIT POWER SUPPLY CIRCUIT
• Are the keyless control module power supply and voltage normal?
- IG1 signal (terminal 3B)
- B+ signal (terminal 1E, 1F)
|
Yes
|
Go to the next step.
|
No
|
• Inspect for a burnt fuse.
• Inspect the power supply system wiring harness for an open or short circuit.
|
5
|
INSPECT KEYLESS UNIT GROUND CIRCUIT
• Is the keyless control module ground voltage normal?
- 0V (terminal 1B, 3C)
|
Yes
|
Go to the next step.
|
No
|
Inspect the ground system wiring harness for an open circuit.
|
6
|
INSPECT LATCH SWITCH SIGNAL VOLTAGE
• Are the wiring harnesses between the keyless control module and each door switch normal?
-
- Inspect each terminal (4O and 4T) under the following conditions.
-
• Door closed: B+
-
• Door open: 2.0V or less
|
Yes
|
Go to the next step.
|
No
|
• Inspect the door switch.
• Inspect the door switch system wiring harness for a short circuit.
|
7
|
INSPECT KEYLESS SWITCH
• Is the keyless switch normal?
|
Yes
|
Replace the keyless control module.
|
No
|
Replace the keyless switch.
|
8
|
INSPECT DOOR LOCK ACTUATOR OPERATION SIGNAL
• Is the signal voltage transmitted to the door lock actuator normal?
• Does the signal voltage transmitted to the door lock actuator change as follows when the malfunction diagnosis inspection procedure is performed.
-
- All doors locked: Cycles 1.0 V or less →B+→1.0 V or less (terminal 1A)
-
- All doors unlocked: Cycles B+→1.0 V or less→B+ (terminal 1C)
|
Yes
|
Go to the next step.
|
No
|
• Inspect the wiring harness between the keyless control module and the door lock actuator for an open or short circuit.
• Inspect the door lock actuator.
|
9
|
INSPECT TURN LIGHT SIGNAL VOLTAGE
• Is the signal voltage transmitted to each turn light normal?
• Does the signal voltage transmitted to each turn light change as follows when the malfunction diagnosis inspection procedure is performed.
-
- Alternates between 1.0 or less and B+ (terminal 4N)
|
Yes
|
Verify the malfunction symptom again.
|
No
|
• Inspect the wiring harnesses between the keyless entry module and each turn light for a short circuit.
• Inspect each turn light.
|