POWER RETRACTABLE HARDTOP SWITCH CONSTRUCTION/OPERATION
id091600102000
• The power retractable hardtop switch is integrated with the hazard warning switch.
• The operational switch operates at the point the switch has been continuously pressed on for 100 ms.
• Depending on the power retractable hardtop position and operation conditions, the operation switch input reception is restricted as follows:
Power retractable hardtop position
|
Power retractable hardtop open switch input
|
Power retractable hardtop close switch input
|
Power retractable hardtop operation after switch determined to be on/off
|
Restriction
|
Power retractable hardtop position
|
Power retractable hardtop operation
|
Full open
|
Stopped
|
ON
|
OFF
|
Stop
|
power retractable hardtop open switch inoperative
|
Full closed
|
Stopped
|
OFF
|
On operation
|
Stop
|
power retractable hardtop close switch inoperative
|
All positions
|
Stopped
|
ON at the same time
|
ON at the same time
|
Stop
|
power retractable hardtop open and close switch inoperative
|
Full open
|
Stopped
|
During ON
|
Operates afterward
|
Stop
|
power retractable hardtop close switch inoperative
|
Full closed
|
Stopped
|
Operates afterward
|
During ON
|
Stop
|
power retractable hardtop open switch inoperative
|
Except fully open
|
During open operation
|
During ON
|
On operation afterward
|
operations stop
|
power retractable hardtop open and close switch inoperative
|
Except fully closed
|
During close operation
|
On operation afterward
|
During ON
|
operations stop
|
power retractable hardtop open and close switch inoperative
|
• Once the operation switch has operated, the next operation switch does not operate unless an off-operation for the switch operation is detected.