DLC-2 OUTLINE [SJ6A-EL]


id050208100900

•  A connector (DLC-2) conforming to International Organization for Standardization (ISO) standards has been added.
•  Shape and terminal arrangement as stipulated by the ISO 15031-3 (SAE J1962) international standard has been adopted for this connector. The connector has a 16-pin construction that includes the B+, CAN_H, CAN_L, GND1, GND2 and KLN terminals.
amxzzn00000079

Terminal

Function

B+
Battery power supply terminal
CAN_L
Serial communication Lo terminal
CAN_H
Serial communication Hi terminal
GND1
Body ground terminal
GND2
Serial communication ground terminal
KLN
Serial communication terminal (malfunction diagnosis use)