NO.2 AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE [MANUAL AIR CONDITIONER]
id0703c2800500
2
|
Amount of air blown from vents does not change.
|
DESCRIPTION
|
• Malfunction in blower system.
|
POSSIBLE CAUSE
|
• Malfunction in A/C unit
• Malfunction in blower motor
• Malfunction in power MOS FET system
• Malfunction in climate control unit
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT HEATER 40 A FUSE
• Inspect HEATER 40 A fuse.
• Is it okay?
|
Yes
|
Go to the next step.
|
No
|
Replace fuse, then go to Step 15. If fuse burns out immediately, go to the next step.
|
||
2
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN A/C UNIT OR ELSEWHERE
• Switch the ignition to ON.
• Turn the fan switch to ON position.
• Recirculate air inside vehicle.
• Does blower fan rotate smoothly?
|
Yes
|
Go to Step 4.
|
No
|
Go to the next step.
|
||
3
|
INSPECT AIR DIST UNIT INTAKE VENT
• Is intake vent of air dist unit clogged?
|
Yes
|
Remove obstruction, then go to Step 15.
|
No
|
Inspect if there are any obstruction in passage between air dist unit to A/C unit, then go to Step 15.
|
||
4*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER RELAY SYSTEM OR POWER MOS FET SYSTEM
• Switch the ignition to ON.
• Turn the fan switch to OFF position.
• Test voltage at the following terminal of blower motor.
• Is voltage approx. 12 V?
|
Yes
|
Go to Step 8.
|
No
|
Go to the next step.
|
||
5*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN FUSE BLOCK AND BLOWER RELAY) OR ELSEWHERE
• Test voltage at the following terminal of blower relay.
• Is voltage approx. 12 V?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness between blower relay and HEATER 40 A fuse, then go to Step 15.
|
||
6*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER RELAY AND GROUND) OR ELSEWHERE
• Test voltage at the following terminal of blower relay.
• Is voltage approx. 0 V?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness between blower relay and ground, then go to Step 15.
|
||
7*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER RELAY AND BLOWER MOTOR) OR BLOWER RELAY
• Test voltage at the following terminal of blower relay.
• Is voltage approx. 12 V?
|
Yes
|
Repair wiring harness between blower relay and blower motor, then go to Step 15.
|
No
|
Replace blower relay, then go to Step 15.
|
||
8*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER MOTOR OR ELSEWHERE
• Test voltage at the following terminal of blower motor.
• Is voltage approx. 12 V?
|
Yes
|
Go to the next step.
|
No
|
Inspect blower motor, then go to Step 15.
|
||
9*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER MOTOR AND POWER MOS FET) OR ELSEWHERE
• Test voltage at the following terminal of power MOS FET.
• Is voltage approx. 12 V?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness between blower motor and power MOS FET, then go to Step 15.
|
||
10*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN POWER MOS FET AND GROUND) OR ELSEWHERE
• Test voltage at the following terminal of power MOS FET.
• Is voltage approx. 0 V?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness between power MOS FET and ground, then go to Step 15.
|
||
11
|
INSPECT A/C UNIT
• Inspect fan in A/C unit.
• Is fan okay?
|
Yes
|
Go to the next step.
|
No
|
Remove obstruction, repair or replace fan and A/C unit case, then go to Step 15.
|
||
12*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN POWER MOS FET OR ELSEWHERE
• Disconnect power MOS FET connector.
• Turn the fan switch to 1st position from off.
• Test voltage at the following terminal of power MOS FET.
• Is voltage approx. 10 V?
|
Yes
|
Replace power MOS FET, then go to Step 15.
|
No
|
Go to the next step.
|
||
13*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN POWER MOS FET AND CLIMATE CONTROL UNIT) OR ELSEWHERE
• Switch the ignition to off.
• Disconnect climate control unit connector.
• Inspect for continuity at the following terminals between power MOS FET and climate control unit.
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness between power MOS FET and climate control unit, then go to Step 15.
|
||
14*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR WIRING HARNESS (SHORT TO GROUND BETWEEN POWER MOS FET AND CLIMATE CONTROL UNIT)
• Inspect for continuity at the following terminal between power MOS FET and ground.
• Is there continuity?
|
Yes
|
Repair wiring harness between power MOS FET and ground, then go to the next step.
|
No
|
Replace climate control unit, then go to the next step.
|
||
15
|
CONFIRM THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
• Is air discharged from vent?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|