DTC TABLE [POWER RETRACTABLE HARDTOP]


id0902j2960500

DTC

description

Page

M-MDS display

B1342
Power retractable hardtop control module internal malfunction
B1317
Battery power supply voltage increases (17.5 V or more)
B1318
Battery power supply voltage decreases (less than 7.5 V)
B296D
Hall sensor low power supply voltage
U0030
Power window communication error (during power retractable hardtop operation)
U0031
Power window communication error (during power retractable hardtop not operation)
B296A
Roof motor pulse signal error (RH)
B294B
Roof motor pulse signal error (LH)
B293C
Deck panel motor pulse signal error (RH)
B293B
Deck panel motor pulse signal error (RL)
B293E
Roof motor circuit malfunction (RH)
B293D
Roof motor circuit malfunction (LH)
B294C
Deck panel motor circuit malfunction (RH)
B293F
Deck panel motor circuit malfunction (LH)
B294D
Roof motor opening angle does not match (Pulse count number do not match)
B294E
Deck panel motor opening angle does not match (Pulse count number do not match)
B294F
Power retractable hardtop/deck panel limit switch malfunction
B296B
Top lock switch malfunction
B296C
Power retractable hardtop switch malfunction
U0073
CAN system communication error
U0100
Communication error to PCM
U0101
Communication error to TCM
U2197
Vehicle speed signal communication error