POWER WINDOW MAIN SWITCH INSPECTION
id091200419000
Auto Close Function (All Door)
1. Measure the voltage at each terminal (other than terminal A and H).
2. Remove the battery cover.
3. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [L8, LF].)
4. Inspect the power window main switch connector for continuity at terminal A and H.
amxzzw00002491
|
Terminal |
Signal name |
Connected to |
Measured condition |
Voltage (V)/Continuity |
Inspection item (s) |
---|---|---|---|---|---|
A
|
Communication
|
Power retractable hardtop control module
|
Instant when door glass open operation is completed after RHT switch is operation
|
1.0 or less (See Reference.)
|
• Power retractable hardtop control module
• Related wiring harnesses
|
Other
|
B+
|
||||
B
|
IG 1
|
P.WIND 20 A fuse
|
Switch the ignition to ON
|
B+
|
• P.WIND 20 A fuse
• Related wiring harnesses
|
Switch the ignition to LOCK
|
1.0 or less
|
||||
D
|
Close output
|
Power window motor (RH)
|
While door glass is opening
|
1.0 or less
|
• Power window motor (See POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
While door glass is closing
|
B+
|
||||
F
|
Open output
|
Power window motor (RH)
|
While door glass is opening
|
B+
|
• Power window motor (See POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
While door glass is closing
|
1.0 or less
|
||||
G
|
GND
|
Body ground
|
Under any condition
|
1.0 or less
|
• GND
|
H
|
Communication
|
Power retractable hardtop control module
|
While RHT switch is pressed
|
1.0 or less
|
• Power retractable hardtop control module
• Related wiring harnesses
|
While RHT switch is not pressed
|
B+
|
||||
I
|
Close output
|
Power window motor (LH)
|
While door glass is opening
|
1.0 or less
|
• Power window motor (See POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
While door glass is closing
|
B+
|
||||
J
|
Open output
|
Power window motor (LH)
|
While door glass is opening
|
B+
|
• Power window motor (See POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
While door glass is closing
|
1.0 or less
|
Reference
amxzzw00002556
|
Auto Close Function (Driver's Door Only)
1. Measure the voltage at each terminal.
amxzzw00002491
|
Terminal |
Signal name |
Connected to |
Measured condition |
Voltage (V) |
Inspection item (s) |
---|---|---|---|---|---|
A
|
Close output
|
Power window motor (RH)
|
While door glass is opening
|
1.0 or less
|
• Power window motor (See POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
While door glass is closing
|
B+
|
||||
B
|
Open output
|
Power window motor (LH)
|
While door glass is opening
|
B+
|
• Power window motor (See POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
While door glass is closing
|
1.0 or less
|
||||
D
|
Open output
|
Power window motor (RH)
|
While door glass is opening
|
B+
|
• Power window motor (See POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
While door glass is closing
|
1.0 or less
|
||||
F
|
—
|
—
|
—
|
—
|
—
|
G
|
Close output
|
Power window motor (LH)
|
While door glass is opening
|
1.0 or less
|
• Power window motor (See POWER WINDOW MOTOR INSPECTION.)
• Related wiring harnesses
|
While door glass is closing
|
B+
|
||||
H
|
—
|
—
|
—
|
—
|
—
|
I
|
IG 1
|
P.WIND 20 A fuse
|
Switch the ignition to ON
|
B+
|
• P.WIND 20 A fuse
• Related wiring harnesses
|
Switch the ignition to LOCK
|
1.0 or less
|
||||
J
|
GND
|
Body ground
|
Under any condition
|
1.0 or less
|
• GND
|