POWER WINDOW MAIN SWITCH INSPECTION


id091200419000


Auto Close Function (All Door)

1.  Measure the voltage at each terminal (other than terminal A and H).

•  If the voltage is not as specified in the terminal voltage table, inspect the parts under “Inspection item (s)” and related wiring harnesses.

2.  Remove the battery cover.

3.  Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [L8, LF].)

4.  Inspect the power window main switch connector for continuity at terminal A and H.

•  If the system does not work properly even though the inspection items or related wiring harnesses do not have any malfunction, replace the power window main switch.
amxzzw00002491

Terminal

Signal name

Connected to

Measured condition

Voltage (V)/Continuity

Inspection item (s)

A
Communication
Power retractable hardtop control module
Instant when door glass open operation is completed after RHT switch is operation
1.0 or less (See Reference.)
•  Power retractable hardtop control module
•  Related wiring harnesses
Other
B+
B
IG 1
P.WIND 20 A fuse
Switch the ignition to ON
B+
•  P.WIND 20 A fuse
•  Related wiring harnesses
Switch the ignition to LOCK
1.0 or less
D
Close output
Power window motor (RH)
While door glass is opening
1.0 or less
•  Power window motor (See POWER WINDOW MOTOR INSPECTION.)
•  Related wiring harnesses
While door glass is closing
B+
F
Open output
Power window motor (RH)
While door glass is opening
B+
•  Power window motor (See POWER WINDOW MOTOR INSPECTION.)
•  Related wiring harnesses
While door glass is closing
1.0 or less
G
GND
Body ground
Under any condition
1.0 or less
•  GND
H
Communication
Power retractable hardtop control module
While RHT switch is pressed
1.0 or less
•  Power retractable hardtop control module
•  Related wiring harnesses
While RHT switch is not pressed
B+
I
Close output
Power window motor (LH)
While door glass is opening
1.0 or less
•  Power window motor (See POWER WINDOW MOTOR INSPECTION.)
•  Related wiring harnesses
While door glass is closing
B+
J
Open output
Power window motor (LH)
While door glass is opening
B+
•  Power window motor (See POWER WINDOW MOTOR INSPECTION.)
•  Related wiring harnesses
While door glass is closing
1.0 or less


Reference

amxzzw00002556
•  Terminal connected: A (+) — Body ground
•  Oscilloscope setting: 2 V/DIV (Y): 500 ms/DIV (X), DC range
•  Measurement condition: RHT switch is pressed

Auto Close Function (Driver's Door Only)

1.  Measure the voltage at each terminal.

•  If the voltage is not as specified in the terminal voltage table, inspect the parts under “Inspection item (s)” and related wiring harnesses.
―  If the system does not work properly even though the inspection items or related wiring harnesses do not have any malfunction, replace the power window main switch.

amxzzw00002491

Terminal

Signal name

Connected to

Measured condition

Voltage (V)

Inspection item (s)

A
Close output
Power window motor (RH)
While door glass is opening
1.0 or less
•  Power window motor (See POWER WINDOW MOTOR INSPECTION.)
•  Related wiring harnesses
While door glass is closing
B+
B
Open output
Power window motor (LH)
While door glass is opening
B+
•  Power window motor (See POWER WINDOW MOTOR INSPECTION.)
•  Related wiring harnesses
While door glass is closing
1.0 or less
D
Open output
Power window motor (RH)
While door glass is opening
B+
•  Power window motor (See POWER WINDOW MOTOR INSPECTION.)
•  Related wiring harnesses
While door glass is closing
1.0 or less
F
G
Close output
Power window motor (LH)
While door glass is opening
1.0 or less
•  Power window motor (See POWER WINDOW MOTOR INSPECTION.)
•  Related wiring harnesses
While door glass is closing
B+
H
I
IG 1
P.WIND 20 A fuse
Switch the ignition to ON
B+
•  P.WIND 20 A fuse
•  Related wiring harnesses
Switch the ignition to LOCK
1.0 or less
J
GND
Body ground
Under any condition
1.0 or less
•  GND