ROOF MOTOR INSPECTION


id091600809800

1.  Apply battery positive voltage and connect the ground to roof motor terminals A and E, and then inspect the roof motor operation.

e5e916zw6y01

•  If the roof motor does not operate as indicated in the table, replace it.
Caution
•  If the roof motor temperature is high, the motor may not rotate due to the motor internal PTC function. Leave it untouched for about 3 min to cool it down, then reinspect.

Operation

Terminal

E

A

Open
B+
Ground
Close
Ground
B+

2.  Connect the battery positive voltage to roof motor terminal B and connect terminal F to ground.

3.  Operate the roof motor and measure the voltage at terminal D.

•  If there is any malfunction, replace the roof motor.
Voltage
•  Pulse: max. 13 V/min. 0 V