BATTERY [SKYACTIV-G 1.5, SKYACTIV-G 2.0]
id0117t2185200
Purpose, Function
Construction
amxzzn00000736
|
Fail-safe
DTC |
Fail-safe |
---|---|
P057F:00
|
• Inhibits engine-stop by operating the i-stop function. (Vehicles with i-stop system)
• Inhibits the i-ELOOP control. (Vehicles with i-stop system)
|
P0A0F:00
|
• Flashes the i-stop warning light (amber) and inhibits engine-stop by operating the i-stop function. (Vehicles with i-stop system)
|
P0A8D:00
|
• Inhibits engine-stop by operating the i-stop function. (Vehicles with i-stop system)
• Inhibits the i-ELOOP control. (Vehicles with i-stop system)
|
P0A8F:00
|
|
P2502:00
|
• Generator control is inhibited. (Vehicles without i-ELOOP)
• Inhibits engine-stop by operating the i-stop function. (Vehicles with i-ELOOP)
• Generator switch to default mode requested (14.5 V constant voltage power generation). (Vehicles with i-ELOOP)
• Transition to i-ELOOP bypass mode. (Vehicles with i-ELOOP)
|
P2503:00
|
|
P2504:00
|
• Generator control is inhibited. (Vehicles without i-ELOOP)
• Inhibits engine-stop by operating the i-stop function. (Vehicles with i-ELOOP)
• Generator switch to default mode requested. If the temperature of the generator exceeds the specified value, the generator itself stops power generation. But, if the internal circuit of the generator is malfunctioning, the generator may not accept the demand from the PCM. (Vehicles with i-ELOOP)
|