NEUTRAL SWITCH INSPECTION [SKYACTIV-G 1.5, SKYACTIV-G 2.0]


id0140g8800800


Neutral Switch No.1


Continuity inspection

1.  Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)

2.  Remove the neutral switch No.1. (See NEUTRAL SWITCH REMOVAL/INSTALLATION [M66M-D].)

3.  Inspect for continuity between neutral switch No.1 terminal A and D.

amxzzw00005540

•  If not as specified, replace the neutral switch No.1. (See NEUTRAL SWITCH REMOVAL/INSTALLATION [M66M-D].)

Specification

Measured condition

Continuity

Rod pushed
Continuity detected
Rod not pushed
No continuity


Neutral Switch No.2 (With i-stop System)


Continuity inspection

1.  Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)

2.  Remove the neutral switch No.2. (See NEUTRAL SWITCH REMOVAL/INSTALLATION [M66M-D].)

3.  Inspect for continuity between neutral switch No.2 terminal A and D.

amxzzw00005541

•  If not as specified, replace the neutral switch No.2. (See NEUTRAL SWITCH REMOVAL/INSTALLATION [M66M-D].)

Specification

Measured condition

Continuity

Rod pushed
Continuity detected
Rod not pushed
No continuity