DTC C101C:71 [EVP CONTROL UNIT]
id040251839400
DTC
|
C101C:71
|
Electric vacuum pump: stuck
|
DETECTION CONDITION
|
• Electric vacuum pump drive circuit electrical current is high for a continuous 3 s when the electric vacuum pump is operated.
|
|
FAIL-SAFE FUNCTION
|
• Refer to “Fail-safe function table”. (See DTC TABLE [EVP CONTROL UNIT].)
|
|
POSSIBLE CAUSE
|
• EVP control unit power supply circuit malfunction
• EVP control unit malfunction
|
|
SYSTEM WIRING DIAGRAM
|
—
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
RECORD SNAPSHOT DATA TO UTILIZE WITH REPEATABILITY VERIFICATION
• Record the snapshot data on the repair order.
|
—
|
Go to the next step.
|
2
|
VERIFY DTC REPEATABILITY
• Using the M-MDS, clear the DTC from the EVP control unit.
• Switch the ignition ON (engine off).
• Access the VP_C PID and simulation item VPS_FBK using the M-MDS.
• Verify PID VP_C when the electric vacuum pump is operated by simulation item VPS_FBK.
• Is the VP_C PID 60 A or more?
|
Yes
|
Replace the electric vacuum pump, then go to Step 5.
|
No
|
Go to the next step.
|
||
3
|
DRIVE VEHICLE THEN VERIFY DTC REPEATABILITY BASED ON SERVICE QUESTIONING RESULTS AND SNAPSHOT DATA
• Switch the ignition ON (engine off).
• Access the VP_C PID and simulation item VPS_FBK using the M-MDS.
• Drive the vehicle based on the service questions content and snapshot data driving conditions.
• Is the VP_C PID 60 A or more, while the vehicle is driven?
|
Yes
|
Replace the electric vacuum pump, then go to Step 5.
|
No
|
Go to the next step.
|
||
4
|
VERIFY DTC REPEATABILITY AND DETERMINE IF MALFUNCTION CAUSE IS EVP CONTROL UNIT
• Using the M-MDS, clear the DTC from the EVP control unit.
• Switch the ignition ON (engine off).
• Using the M-MDS, perform the EVP control unit DTC inspection.
• Is the same Pending DTC present?
|
Yes
|
Replace the EVP control unit, then go to Step 6.
|
No
|
DTC troubleshooting completed.
Explain to the customer that there are no malfunctions with the vehicle based on the contents of the servicing.
|
||
5
|
VERIFY DTC TROUBLESHOOTING COMPLETED
• Using the M-MDS, clear the DTC from the EVP control unit.
• Using the M-MDS, perform the EVP control unit DTC inspection.
• Is the same Pending DTC present?
|
Yes
|
Repeat the inspection from Step1.
If the malfunction recurs, replace the EVP control unit, then go to the next step.
|
No
|
Go to the next step.
|
||
6
|
VERIFY NO DTC IS PRESENT
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
(See DTC TABLE [EVP CONTROL UNIT].)
|
No
|
DTC troubleshooting completed.
|